Tandems with FI on the primary compressor (60 Hz)

The following table lists all possible Orbit tandem compounds with 60 Hz supply frequency and frequency inverter on the primary compressor.

In each tandem or trio, one compressor is the primary compressor. This should be the compressor with the lowest displacement in the tandem, because it is the first to receive oil from the BAHT header:

To identify the mounting position which is indicated by "primary" and "secondary compressor", please contact Bitzer for the respective compound assembly drawings.

Orbit tandem compounds with 60 Hz supply frequency (=f (fix)) and frequency inverter on the primary compressor
f (min.): minimum permitted frequency
f (max.): maximum permitted frequency

Primary compressor

f (min.)

f (max.)

Secondary compressor

f (fix)

GSD80295

35 Hz

75 Hz

GSD80385

60 Hz

GSD80295

35 Hz

75 Hz

GSD80421

60 Hz

GSD80295

35 Hz

75 Hz

GSD80485

60 Hz

GSD80385

35 Hz

65 Hz

GSD80421

60 Hz

GSD80385

35 Hz

75 Hz

GSD80485

60 Hz

GSD80421

35 Hz

69 Hz

GSD80485

60 Hz

GSD60120

35 Hz

68 Hz

GSD60137

60 Hz

GSD60120

35 Hz

75 Hz

GSD60154

60 Hz

GSD60137

35 Hz

67 Hz

GSD60154

60 Hz

GSD60120

35 Hz

75 Hz

GSD60182

60 Hz

GSD60137

35 Hz

75 Hz

GSD60182

60 Hz

GSD60154

35 Hz

70 Hz

GSD60182

60 Hz

GSD60120

35 Hz

75 Hz

GSD60235

60 Hz

GSD60137

35 Hz

75 Hz

GSD60235

60 Hz

GSD60154

35 Hz

75 Hz

GSD60235

60 Hz

GSD60182

35 Hz

75 Hz

GSD60235

60 Hz

GSD60120

35 Hz

60 Hz

GSD80295

60 Hz

GSD60137

35 Hz

60 Hz

GSD80295

60 Hz

GSD60154

35 Hz

60 Hz

GSD80295

60 Hz

GSD60182

35 Hz

60 Hz

GSD80295

60 Hz

GSD60120

35 Hz

75 Hz

GSD80385

60 Hz

GSD60137

35 Hz

75 Hz

GSD80385

60 Hz

GSD60235

35 Hz

60 Hz

GSD80295

60 Hz

GSD60154

35 Hz

75 Hz

GSD80385

60 Hz

GSD60120

35 Hz

75 Hz

GSD80421

60 Hz

GSD60137

35 Hz

75 Hz

GSD80421

60 Hz

GSD60182

35 Hz

65 Hz

GSD80385

60 Hz

GSD60154

35 Hz

75 Hz

GSD80421

60 Hz

GSD60182

35 Hz

75 Hz

GSD80421

60 Hz

GSD60120

35 Hz

75 Hz

GSD80485

60 Hz

GSD60235

35 Hz

60 Hz

GSD80385

60 Hz

GSD60137

35 Hz

75 Hz

GSD80485

60 Hz

GSD60154

35 Hz

75 Hz

GSD80485

60 Hz

GSD60235

35 Hz

65 Hz

GSD80421

60 Hz

GSD60182

35 Hz

75 Hz

GSD80485

60 Hz

GSD60235

35 Hz

70 Hz

GSD80485

60 Hz

GSD60120

35 Hz

60 Hz

GSD60120

60 Hz

GSD60137

35 Hz

60 Hz

GSD60137

60 Hz

GSD60154

35 Hz

60 Hz

GSD60154

60 Hz

GSD60182

35 Hz

60 Hz

GSD60182

60 Hz

GSD60235

35 Hz

60 Hz

GSD60235

60 Hz

GSD80295

35 Hz

60 Hz

GSD80295

60 Hz

GSD80385

35 Hz

60 Hz

GSD80385

60 Hz

GSD80421

35 Hz

60 Hz

GSD80421

60 Hz

GSD80485

35 Hz

60 Hz

GSD80485

60 Hz