Dimensions and refrigerant connections: standard design

Versions for 4 passes and 2 passes are only listed separately, if the dimensions are different.

Detailed dimensions of the reversing covers see Cover dimensions and heat transfer fluid connections.

In the case of a pressure equipment that has been subjected to an approval procedure for a marine application, the fastening support of the lower fixing brackets is designed more solidly. This makes it up to 9 mm higher. This applies to dimensions C, E1, L and S. The foot spacing 740 mm (dimension H) is also reduced to 680 mm. For the models concerned, dimension I is 30 mm larger as a result.

K033N(P), K033H(P), K073H(P) and K123H(P)

Model

A

A1

B

B1

C

C1

D

E

E1

F

G

H

I

K033N(P)

606

517

152

130

184

108

50

154

50

110

400

58

K033H(P)

606

517

152

130

184

108

50

154

50

110

400

58

K073H(P)

606

517

152

130

184

108

50

154

50

110

400

58

K123H(P)

856

767

152

130

172

108

60

154

60

110

400

188

Model

L

R

R1

S

T

U

U1

U2

V

W

X

Y

Z

K033N(P)

60

45

62

212

250

47

6

87

K033H(P)

125

60

45

62

132

236

212

250

47

6

87

K073H(P)

125

60

45

62

132

236

212

250

47

6

87

K123H(P)

125

60

50

62

262

295

275

320

47

6

87

No additional refrigerant outlet available.

Model

Refrigerant connections, positions 1 and 2

bushing

thread/flange

inlet Ø

outlet Ø

inlet

outlet

mm

inch

mm

inch

K033N(P)

12

1/2

10

3/8

1-14 UNS

3/4-16 UNF

K033H(P)

12

1/2

10

3/8

1-14 UNS

3/4-16 UNF

K073H(P)

12

1/2

10

3/8

1-14 UNS

3/4-16 UNF

K123H(P)

16

5/8

12

1/2

1-14 UNS

1-14 UNS

K203H(P), K283H(P), K373H(P), K573H(P), K813H(P) and K1053H(P)

Model

A

A1

B

B1

C

C1

D

E

E1

F

G

H

I

K203H(P)

860

767

197

130

234

159

60

213

60

110

400

184

K283H(P)

860

767

197

130

242

159

60

223

60

110

400

184

K373H(P)

1110

1017

197

130

248

159

60

223

60

110

740

138

K573H(P)

1176

1070

245

200

308

216

60

279

60

180

740

165

K813H(P)

1176

1070

245

200

308

216

60

279

60

180

740

165

K1053H(P)

1634

1528

245

200

324

216

70

279

70

180

900

314

Model

L

R

R1

S

T

U

U1

U2

V

W

X

Y

Z

K203H(P)

190

60

50

95

218

335

275

320

52

8

113

K283H(P)

190

60

50

95

218

335

275

320

52

8

113

K373H(P)

190

60

50

95

344

335

275

320

52

8

113

K573H(P)

236

60

50

118

300

381

305

360

53

8

133

K813H(P)

236

60

50

118

300

381

305

360

53

8

133

K1053H(P)

236

130

70

118

300

381

305

360

53

8

133

Special design only for the model K283H(P): Additional refrigerant outlet below on the refrigerant inlet side:
Position 2a, see dimensions of the corresponding seawater resistant design.
The connection is delivered with sealing nut or blind flange, if desired also with a valve.

Model

Refrigerant connections, positions 1 and 2

bushing

thread/flange

inlet Ø

outlet Ø

inlet

outlet

mm

inch

mm

inch

K203H(P)

16

5/8

16

5/8

1-1/4-12 UNF

1-14 UNS

K283H(P)

22

7/8

22

7/8

1 1/4-12 UNF

1 1/4-12 UNF

K373H(P)

28

1 1/8

22

7/8

1 3/4-12 UN

1 1/4-12 UNF

K573H(P)

35

1 3/8

28

1 1/8

1 3/4-12 UN

1 3/4-12 UN

K813H(P)

35

1 3/8

28

1 1/8

1 3/4-12 UN

1 3/4-12 UN

K1053H(P)

42

1 5/8

35

1 3/8

2 1/4-12 UN

1 3/4-12 UN

K1353T(P), K1973T(P), K2923T(P), K3803T(P), K4803T(P), K6703N, K6703T, K8503N and K8503T

Model

A

A1

B

B1

C

C1

D

E

E1

F

G

H

I

K1353T(P)

1634

1528

245

200

394

324

216

70

27

70

180

900

314

K1973T(P)-4

1661

1527

333

280

541

401

298

102

95

102

250

900

314

K1973T(P)-2

1694

1527

333

280

541

401

298

102

95

102

250

900

314

K2923T(P)-4

1661

1527

333

280

561

401

298

102

88

102

250

900

322

K2923T(P)-2

1694

1527

333

280

561

401

298

102

88

102

250

900

322

K3803T(P)-4

1739

1519

391

280

684

484

368

110

112

110

250

900

310

K3803T(P)-2

1749

1519

391

280

684

484

368

110

112

110

250

900

310

K4803T(P)-4

1739

1519

391

280

684

484

368

110

112

110

250

900

310

K4803T(P)-2

1749

1519

391

280

684

484

368

110

112

110

250

900

310

K6703N-4

1816

1528

344

335

843

642

500

125

111

125

305

900

314

K6703N-2

1813

1528

344

335

843

642

500

125

111

125

305

900

314

K6703T-4

1816

1528

344

335

843

642

500

125

111

125

305

900

314

K6703T-2

1813

1528

344

335

843

642

500

125

111

125

305

900

314

K8503N-4

1816

1528

344

335

843

642

500

125

111

125

305

900

314

K8503N-2

1813

1528

344

335

843

642

500

125

111

125

305

900

314

K8503T-4

1816

1528

344

335

843

642

500

125

111

125

305

900

314

K8503T-2

1813

1528

344

335

843

642

500

125

111

125

305

900

314

Model

L

R

R1

S

T

U

U1

U2

V

W

X

Y

Z

K1353T(P)

236

130

70

118

117

381

381

381

305

360

53

70

133

K1973T(P)-4

337

80

70

169

108

381

381

381

305

360

67

140

178

K1973T(P)-2

337

80

70

169

108

381

381

381

305

360

100

140

178

K2923T(P)-4

337

80

80

169

108

381

381

381

360

420

67

160

178

K2923T(P)-2

337

80

80

169

108

381

381

381

360

420

100

160

178

K3803T(P)-4

413

80

80

205

106

381

381

381

360

420

130

200

201

K3803T(P)-2

413

80

80

205

106

381

381

381

360

420

140

200

201

K4803T(P)-4

413

80

80

205

106

381

381

381

360

420

130

200

201

K4803T(P)-2

413

80

80

205

106

381

381

381

360

420

140

200

201

K6703N-4

545

80

80

374

360

420

185

200

244

K6703N-2

545

80

80

374

360

420

182

200

244

K6703T-4

545

80

80

374

111

381

381

381

360

420

185

200

244

K6703T-2

545

80

80

374

111

381

381

381

360

420

182

200

244

K8503N-4

545

80

80

374

360

420

185

200

244

K8503N-2

545

80

80

374

360

420

182

200

244

K8503T-4

545

80

80

374

111

381

381

381

360

420

185

200

244

K8503T-2

545

80

80

374

111

381

381

381

360

420

182

200

244

Additional refrigerant outlet below on the refrigerant inlet side: special design for the models K1053H(P) to K4803T(P)
Position 2a see dimensions of the corresponding seawater resistant design.
K1053H(P) and K1353T(P): 1 3/4-12 UNF, K1973T(P): 2 1/4-12 UNF, K2923T(P): DN50, K3803T(P) and K4803T(P): DN80
The connection is delivered with sealing nut or blind flange, if desired also with a valve.

Model

Refrigerant connections, positions 1 and 2

bushing

thread/flange

inlet Ø

outlet Ø

inlet

outlet

mm

inch

mm

inch

K1353T(P)

42

1 5/8

35

1 3/8

2 1/4-12 UN

1 3/4-12 UN

K1973T(P)

54

2 1/8

42

1 5/8

DN50

2 1/4-12 UN

K2923T(P)

54

2 1/8

54

2 1/8

DN50

DN50

K3803T(P)

76

3 1/8

76

3 1/8

DN80

DN80

K4803T(P)

76

3 1/8

76

3 1/8

DN80

DN80

K6703N

76

3 1/8

76

3 1/8

DN100

DN100

K6703T

76

3 1/8

76

3 1/8

DN100

DN100

K8503N

76

3 1/8

76

3 1/8

DN100

DN100

K8503T

76

3 1/8

76

3 1/8

DN100

DN100