Replacement of compressors

The following table lists the most common Bitzer compressors that are no longer available and with which current models they can be replaced (i.e. same footprints, valve positions and valve dimensions).

Technical data incl. motor data of the new compressor may differ from the former model!
notice

Technical data incl. motor data of the new compressor may differ from the former model!

Before replacing the compressor, it is essential to check the technical data of the new compressor, e.g. in the Bitzer Software.

Former Bitzer compressors that are no longer available ("Former model") and their alternatives ("Current model") incl. displacement (V) in m3/h.
Displacement is given at 50 Hz, i.e. at 1450/min for reciprocating compressors and at 2900/min for screw and scroll compressors.
Entries in last column:
X: compressor is replaceable, i.e. identical footprint, valve positions and valve dimensions
X*: height +5 mm, connection dimension identical, secondary oil service connection eliminated (affecting mainly trio compounds)
–: not replaceable

Technology

Former model

V (m3/h)

Current model

V (m3/h)

Replaceable?

reciprocating compressor

2CC-3.2

16,2

2CES-3

16,2

X

reciprocating compressor

2CC-4.2

16,2

2CES-4

16,2

X

reciprocating compressor

2CHC

11,2

2CSL-6

11,2

X

reciprocating compressor

2CL-3.2

16,3

2CES-3

16,2

reciprocating compressor

2CL-4.2

16,3

2CES-4

16,2

reciprocating compressor

2DC-2.2

13,4

2DES-2

13,4

X

reciprocating compressor

2DC-3.2

13,4

2DES-3

13,4

X

reciprocating compressor

2DC-3.F1

13,42

2DES-3.F1

13,42

X

reciprocating compressor

2DHC

9,22

2DSL-5

9,23

X

reciprocating compressor

2DL-2.2

13,3

2DES-2

13,4

reciprocating compressor

2DL-3.2

13,3

2DES-3

13,4

reciprocating compressor

2EC-2.2

11,4

2EES-2

11,4

X

reciprocating compressor

2EC-3.2

11,4

2EES-3

11,4

X

reciprocating compressor

2EC-6.2

11,36

2CSL-6

11,2

X

reciprocating compressor

2EHC

7,81

2ESL-4

7,81

X

reciprocating compressor

2EL-2.2

11,33

2EES-2

11,4

reciprocating compressor

2EL-3.2

11,33

2EES-3

11,4

reciprocating compressor

2FC-2.2

9,54

2FES-2

9,54

X

reciprocating compressor

2FC-3.2

9,54

2FES-3

9,54

X

reciprocating compressor

2FHC

6,36

2FSL-4

6,36

X

reciprocating compressor

2FL-2.2

9,46

2FES-2

9,54

reciprocating compressor

2GC-2.2

7,58

2GES-2

7,58

X

reciprocating compressor

2GHC

5,05

2GSL-3

5,05

X

reciprocating compressor

2GL-2.2

7,56

2GES-2

7,58

reciprocating compressor

2HC-1.2

6,51

2HES-1

6,51

X

reciprocating compressor

2HC-2.2

6,51

2HES-2

6,51

X

reciprocating compressor

2HC-3.2

6,51

2FSL-4

6,36

X

reciprocating compressor

2HHC

4,34

2HSL-3

4,34

X

reciprocating compressor

2HL-1.2

6,56

2HES-1

6,51

reciprocating compressor

2JC-07.2

5,21

2JES-07

5,21

X

reciprocating compressor

2JC-3.2

5,21

2GSL-3

5,05

X

reciprocating compressor

2JHC

3,48

2JSL-2

3,48

X

reciprocating compressor

2KC-05.2

4,06

2KES-05

4,06

X

reciprocating compressor

2KC-3.2

4,06

2HSL-3

4,34

X

reciprocating compressor

2KHC

2,71

2KSL-1

2,71

X

reciprocating compressor

2MHC

1,62

2MSL-07

1,73

X

reciprocating compressor

2N-5.2

28,04

4DES-5

26,8

reciprocating compressor

2N-7.2

28,04

4DES-7

26,8

reciprocating compressor

2Q-4.2

22,14

4EES-4

22,7

reciprocating compressor

2Q-6.2

22,14

4EES-6

22,7

reciprocating compressor

2U-3.2

18,6

4FES-3

18,1

reciprocating compressor

2U-5.2

18,6

4FES-5

18,1

reciprocating compressor

4CC-6.2

32,5

4CES-6

32,5

X

reciprocating compressor

4CC-6.F1

32,48

4CE-6.F1

32,48

X

reciprocating compressor

4CC-9.2

32,5

4CES-9

32,5

X

reciprocating compressor

4CC-9.F3

32,48

4CE-9.F3

32,48

X

reciprocating compressor

4CES-6.F1

32,48

4CE-6.F1

32,48

X

reciprocating compressor

4CES-9.F3

32,48

4CE-9.F3

32,48

X

reciprocating compressor

4CHC

22,3

4CSL-12

22,32

X

reciprocating compressor

4CTC-30

25,6

4CTE-30

26

X

reciprocating compressor

4DC-5.2

26,8

4DES-5

26,8

X

reciprocating compressor

4DC-5.F1

26,84

4DE-5.F1

26,84

X

reciprocating compressor

4DC-7.2

26,8

4DES-7

26,8

X

reciprocating compressor

4DC-7.F1

26,84

4DE-5.F1

26,84

X

reciprocating compressor

4DC-7.F3

26,84

4DE-7.F3

26,84

X

reciprocating compressor

4DES-5.F1

26,84

4DE-5.F1

26,84

X

reciprocating compressor

4DES-7.F3

26,84

4DE-7.F3

26,84

X

reciprocating compressor

4DHC

18,4

4DSL-10

18,45

X

reciprocating compressor

4DTC-25

21,2

4DTE-25

22

X

reciprocating compressor

4EC-4.2

22,7

4EES-4

22,7

X

reciprocating compressor

4EC-6.2

22,7

4EES-6

22,7

X

reciprocating compressor

4EC-6.F1

22,72

4EE-6.F1

22,72

X

reciprocating compressor

4EES-6.F1

22,72

4EE-6.F1

22,72

X

reciprocating compressor

4EHC

15,6

4ESL-9

15,62

X

reciprocating compressor

4FC-3.2

18,1

4FES-3

18,1

X

reciprocating compressor

4FC-5.2

18,1

4FES-5

18,1

X

reciprocating compressor

4FC-5.F1

18,05

4FE-5.F1

18,05

X

reciprocating compressor

4FC-7.2

18,05

4DSL-10

18,45

X

reciprocating compressor

4FES-5.F1

18,05

4FE-5.F1

18,05

X

reciprocating compressor

4FHC

12,4

4FSL-7

12,41

X

reciprocating compressor

4FTC-20

17,8

4FTE-20

17,5

X

reciprocating compressor

4FTC-30

17,8

4FTE-30

17,5

X

reciprocating compressor

4G-20.2

84,6

4GE-23

84,6

X

reciprocating compressor

4G-30.2

84,6

4GE-30

84,6

X

reciprocating compressor

4H-15.2

73,7

4HE-18

73,7

X

reciprocating compressor

4H-25.2

73,7

4HE-25

73,7

X

reciprocating compressor

4HTC-15

12

4HTE-15

12

X

reciprocating compressor

4HTC-20

12

4HTE-20

12

X

reciprocating compressor

4J-13.2

63,5

4JE-15

63,5

X

reciprocating compressor

4J-22.2

63,5

4JE-22

63,5

X

reciprocating compressor

4JTC-10

9,2

4JTE-10

9,3

X

reciprocating compressor

4JTC-15

9,2

4JTE-15

9,3

X

reciprocating compressor

4KTC-10

9,6

4KTE-10

9,6

X

reciprocating compressor

4L-10

49,6

reciprocating compressor

4L-15

49,6

reciprocating compressor

4M-10

57,7

reciprocating compressor

4M-20

57,7

reciprocating compressor

4MTC-10

6,5

4MTE-10

6,6

X

reciprocating compressor

4MTC-7

6,5

4MTE-7

6,6

X

reciprocating compressor

4NCS-12.2

56,2

4NES-14

56,2

X

reciprocating compressor

4NCS-20.2

56,2

4NES-20

56,2

X

reciprocating compressor

4NCS-20.F4

56,25

4NE-20.F4

56,25

X

reciprocating compressor

4NES-14.F3

56,25

4NE-14.F3

56,25

X

reciprocating compressor

4NES-20.F4

56,25

4NE-20.F4

56,25

X

reciprocating compressor

4NHC

46,9

4NSL-30

46,9

X

reciprocating compressor

4PCS-10.2

48,5

4PES-12

48,5

X

reciprocating compressor

4PCS-15.2

48,5

4PES-15

48,5

X

reciprocating compressor

4PCS-15.F4

48,5

4PE-15.F4

48,5

X

reciprocating compressor

4PES-12.F3

48,5

4PE-12.F3

48,5

X

reciprocating compressor

4PES-15.F4

48,5

4PE-15.F4

48,5

X

reciprocating compressor

4PHC

40,4

4PSL-25

40,4

X

reciprocating compressor

4PTC-6

4,3

4PTE-6

4,3

X

reciprocating compressor

4PTC-7

4,3

4PTE-7

5,3

X

reciprocating compressor

4TCS-12.2

41,3

4TES-12

41,3

X

reciprocating compressor

4TCS-12.F4

41,33

4TE-12.F4

41,33

X

reciprocating compressor

4TCS-8.2

41,3

4TES-9

41,3

X

reciprocating compressor

4TES-12.F4

41,33

4TE-12.F4

41,33

X

reciprocating compressor

4TES-9.F3

41,33

4TE-9.F3

41,33

X

reciprocating compressor

4THC

34,4

4TSL-20

34,4

X

reciprocating compressor

4VCS-10.2

34,7

4VES-10

34,7

X

reciprocating compressor

4VCS-10.F4

34,73

4VE-10.F4

34,73

X

reciprocating compressor

4VCS-6.2

34,7

4VES-7

34,7

X

reciprocating compressor

4VES-10.F4

34,73

4VE-10.F4

34,73

X

reciprocating compressor

4VES-7.F3

34,73

4VE-7.F3

34,73

X

reciprocating compressor

4VHC

28,9

4VSL-15

28,9

X

reciprocating compressor

6D-70.2

219,1

8FE-70

221

reciprocating compressor

6E-60.2

183,2

8GE-60

185

reciprocating compressor

6F-40.2

151,6

6FE-44

151,6

X

reciprocating compressor

6F-50.2

151,6

6FE-50

151,6

X

reciprocating compressor

6G-30.2

126,8

6GE-34

126,8

X

reciprocating compressor

6G-40.2

126,8

6GE-40

126,8

X

reciprocating compressor

6H-25.2

110,5

6HE-28

110,5

X

reciprocating compressor

6H-35.2

110,5

6HE-35

110,5

X

reciprocating compressor

6J-22.2

95,3

6JE-25

95,3

X

reciprocating compressor

6J-33.2

96,3

6JE-33

95,3

X

reciprocating compressor

6M-20

86,6

reciprocating compressor

6M-30

86,6

reciprocating compressor

8D-70.2

210,6

8FE-70

221

reciprocating compressor

8E-60.2

184,4

8GE-60

185

reciprocating compressor

8FC-60.2

221

8FE-60

221

X

reciprocating compressor

8FC-70.2

221

8FE-70

221

X

reciprocating compressor

8GC-50.2

185

8GE-50

185

X

reciprocating compressor

8GC-60.2

185

8GE-60

185

X

reciprocating compressor

BHS 1102

39,36

4TES-9

41,3

reciprocating compressor

BHS 111

5,24

2JES-07

5,21

reciprocating compressor

BHS 1252

28,11

4CES-9

32,5

reciprocating compressor

BHS 1282

47,14

4PES-12

48,5

reciprocating compressor

BHS 1452

33,07

4VES-10

34,7

reciprocating compressor

BHS 1522

56,1

4NES-14

56,2

reciprocating compressor

BHS 1702

39,36

4TES-12

41,3

reciprocating compressor

BHS 171

6,56

2HES-1

6,51

reciprocating compressor

BHS 191

7,56

2GES-2

7,58

reciprocating compressor

BHS 2022

47,14

4PES-15

48,5

reciprocating compressor

BHS 231

9,46

2FES-2

9,54

reciprocating compressor

BHS 2402

56,1

4NES-20

56,2

reciprocating compressor

BHS 351

13,3

2DES-2

13,4

reciprocating compressor

BHS 491

11,33

2EES-3

11,4

reciprocating compressor

BHS 502

18,6

4FES-3

18,1

reciprocating compressor

BHS 592

22,14

4EES-4

22,7

reciprocating compressor

BHS 752

28,11

4CES-6

32,5

reciprocating compressor

BHS 802

18,6

4FES-5

18,1

reciprocating compressor

BHS 902

33,07

4VES-7

34,7

reciprocating compressor

BHS 962

22,14

4EES-6

22,7

screw compressor

CSH.1

CSH.5

screw compressor

CSH6551

137

CSH6553

137

X

screw compressor

CSH6561

170

CSH6563

170

X

screw compressor

CSH6581

195

CSH6583

195

X

screw compressor

CSH6591

220

CSH6593

220

X

screw compressor

CSH7551

197

CSH7553

197

X

screw compressor

CSH7561

227

CSH7563

227

X

screw compressor

CSH7571

258

CSH7573

258

X

screw compressor

CSH7581

295

CSH7583

295

X

screw compressor

CSH7583-90Y

295

CSH7583

295

X

screw compressor

CSH7591

336

CSH7593

336

X

screw compressor

CSH7593-100Y

336

CSH7593

336

X

screw compressor

CSH8551

315

CSH8553

315

X

screw compressor

CSH8561

359

CSH8563

359

X

screw compressor

CSH8571

410

CSH8573

410

X

screw compressor

CSH8581

470

CSH8583

470

X

screw compressor

CSH8583-140Y

470

CSH8583

470

X

screw compressor

CSH8591

535

CSH8593

535

X

screw compressor

CSH8593-160Y

535

CSH8593

535

X

screw compressor

CSH95101

1015

CSH95103

1015

X

screw compressor

CSH95111

1120

CSH95113

1120

X

screw compressor

CSH9551

535

CSH9553

535

X

screw compressor

CSH9561

615

CSH9563

615

X

screw compressor

CSH9571

700

CSH9573

700

X

screw compressor

CSH9581

805

CSH9583

805

X

screw compressor

CSH9591

910

CSH9593

910

X

screw compressor

CSW.2

CSW.5

scroll compressor

GSD60120Vxxxx1

19,8

GSD60120Vxxxx2

19,8

X*

scroll compressor

GSD60137Vxxxx1

22,2

GSD60137Vxxxx2

22,2

X*

scroll compressor

GSD60154Vxxxx1

24,8

GSD60154Vxxxx2

24,8

X*

scroll compressor

GSD60182Vxxxx1

29,2

GSD60182Vxxxx2

29,2

X*

scroll compressor

GSD60235Vxxxx1

37,6

GSD60235Vxxxx2

37,6

X*

scroll compressor

GSD80182Vxxxx1

29

scroll compressor

GSD80235Vxxxx1

38,6

GSD80235Vxxxx2

38,6

X

scroll compressor

GSD80295Vxxxx1

48,3

GSD80295Vxxxx2

48,3

X

scroll compressor

GSD80385Vxxxx1

61,8

GSD80385Vxxxx2

61,8

X

scroll compressor

GSD80421Vxxxx1

67,6

GSD80421Vxxxx2

67,6

X

scroll compressor

GSD80485Vxxxx1

77,2

GSD80485Vxxxx2

77,2

X

screw compressor

HSKC

CSH.5

screw compressor

OSKA7441

165

screw compressor

OSKA7451

192

OSKA7452

192

X

screw compressor

OSKA7461

220

OSKA7462

220

X

screw compressor

OSKA7471

250

OSKA7472

250

X

screw compressor

OSNA7441

165

screw compressor

OSNA7451

192

OSNA7452

192

X

screw compressor

OSNA7461

220

OSNA7462

220

X

screw compressor

OSNA7471

250

OSNA7472

250

X